If the indicated pressure is not the discharge pressure required, the machine should be shut
down and the setting procedure repeated.
8.2.5 Operating the machine under load
Precondition The airend discharge temperature must be at least +30 °C
1. Connect the consumer(s) to the compressed air discharge valves.
2. Open the compressed air discharge valves.
8.2.6 Shutting down the machine
1. Close all «compressed air discharge valves» on the air distributor.
The engine is running in IDLE.
2. Turn the «ignition switch» to the “0” position.
The engine switches off.
Decommissioning the machine:
1. Open the enclosure.
2. Turn the «Controller ON» switch to the “0” position.
3. Close the enclosure.
Lock the enclosure if necessary.
8.3 Refuelling the machine
In order to avoid accidents caused by igniting fuel, special caution must be exercised when filling
the fuel tank.
DANGER
Fuel constitutes a fire hazard!
Overflowing or spilled fuel can ignite upon contact with hot engine parts, open flames or
sparks, resulting in serious burns.
➤ Only refuel the machine once it has been switched off and allowed to cool down.
➤ Never refuel the machine in the vicinity of open flames or sparks.
➤ Do not allow fuel to spill or overflow.
➤ Do not smoke.
➤ Follow all instructions carefully.
8.3.1 Using the correct type of fuel
In the worst case scenario, use of the incorrect fuel type in a modern diesel engine can result in
irreparable damage to the injection system and drive engine.
8
Operation
8.3
Refuelling the machine
No.: 9_9548 22 HCE
Operating Manual Portable Rotary Screw Compressor
MOBILAIR M27 PE
71