10.9.4 Option dd
Combination filter maintenance
To ensure proper functioning of the filter combination, you must complete the "Drain condensate"
maintenance task on a daily basis, see Fig. 58.
Overview:
■ Drain condensate
■ Changing the filter element
Precondition The machine is switched off.
The machine is standing level.
The machine is fully vented, the pressure gauge reads 0 bar.
All compressed air consumers are disconnected and the air outlet valves are open.
WARNING
Danger of injury from compressed air!
Filter combination is pressurised during operation. Serious injury can result from loosening
or opening components under pressure.
➤ Wait until the machine has automatically vented (check: pressure gauge reads 0 bar!
➤ De-pressurise the combination filter.
➤ Open the canopy.
10.9.4.1 Drain condensate
Material Receptacle
Cleaning cloths
10 Maintenance
10.9 Maintenance of Optional Items
150
Operating Manual Portable Rotary Screw Compressor
MOBILAIR M27 PE