Fig. 25 Adjusting the tool lubricator
1
Oil separator tank
2
Tool lubricator
3
Lubricant container
4
Metering knob
5
Shut-off valve
I – open
0 – closed
➤ Open the enclosure.
Switch on the lubricant addition:
1. Open the shut-off valve
5
.
2. Close the enclosure.
Setting the lubricant addition amount:
The lubricant content the compressed air should contain depends on the application and must be
determined by the user. It depends on the nature of the pneumatic tools used and the supply hoses
connected.
The amount of lubricant supplied can be adjusted by adjusting the metering wheel:
■ Turning clockwise: Reduce lubricant addition.
■ Turning counter-clockwise: Increase lubricant addition.
1. Set appropriate lubricant addition amount on the metering wheel.
2. Close the enclosure.
Further information Fill the tool lubricator with lubricant (see chapter 10.9.1).
Switch off the lubricant addition:
1. Close the shut-off valve
5
.
2. Close the enclosure.
8
Operation
8.5
Operating the options
80
Operating Manual Portable Rotary Screw Compressor
MOBILAIR M27 PE