Fig. 57 Cleaning the dirt trap
1
Compressed-air aftercooler
2
Compressed air water separator
3
Dirt trap
4
Dirt trap housing
5
Strainer
6
O-ring
7
Screw plug
8
Condensate drain hose
9
Condensate drain hose union nut
10
Nozzle
➤ Raise the cover.
Cleaning the dirt trap
1. Unscrew the plug
7
and remove the strainer
5
.
2. Loosen the union nut
9
and detach the condensate drain hose
8
from the dirt trap
3. Use the small screwdriver to unscrew the nozzle
10
from the dirt trap housing.
4. Clean the nozzle, strainer, screw plug, O-ring
6
and dirt trap housing
4
with cleaning solvent
or spirit.
5. Check the nozzle, strainer and O-ring for wear.
Replace components if they are heavily worn.
6. Place the strainer on the screw plug.
7. Screw in the plug making sure the O-ring seats properly.
8. Screw in the nozzle and re-attach the condensate drain hose.
Putting in operation:
1. Reconnect the negative battery terminal.
2. Close the cover.
Starting the machine and performing a test run:
1. Switch the machine on and run it in IDLE mode for approx. 5 minutes.
2. Shut down the machine.
3. Wait until the machine has automatically vented.
Pressure gauge reads 0 bar!
4. Open the outlet valves.
5. Raise the cover.
6. Check the housing of the water separator and the hose line for leaks.
7. Close the cover.
10 Maintenance
10.9 Maintenance of Optional Items
No.: 9_9548 22 HCE
Operating Manual Portable Rotary Screw Compressor
MOBILAIR M27 PE