8.5.4.2 Switch on the generator
Precondition Read and follow the instructions "Before generator operation.
LOAD mode
A pictogram beneath the generator main switch indicates the correct "cutting-in" of the generator.
Fig. 26 "Generator cut-in" pictogram
1
The compressed air shut-off valves are closed
2
Turn the «generator main switch» to the "l" position.
1. Close the compressed air outlet valves.
2. Turn the «generator main switch »to the "l" position.
3. Turn the «mode selector switch» to the required mode of operation
4. Connect electrical consumers.
Further information See chapter 4.6.3.2 for generator controls.
See chapter 4.6.3.1 for generator operating modes.
8.5.4.3 Disconnect electrical consumers
1. Switch off the electric consumers one after another.
2. Switch off electrical consumers drawing the highest current last.
3. Remove the plugs from the sockets on the generator control cabinet.
4. Check that the protective covers on the power sockets are correctly closed.
8.5.4.4 Switch off the generator
Precondition The electric consumers are switched off.
The plugs are removed.
1.
NOTICE!
Thermal overload of the turbo generator.
Stopping the machine abruptly after the generator has been in operation for some time can
cause heat damage to the generator.
➤ Allow the engine to run for about 2 minutes in idle before shutting down to allow the gener‐
ator to cool down.
8
Operation
8.5
Operating the options
No.: 9_9548 22 HCE
Operating Manual Portable Rotary Screw Compressor
MOBILAIR M27 PE
83