Circuit breaker:
Voltage [V]
115/2~
Safety cut-out [A]
Number:
32
1
16
2
Tab. 55 Circuit breaker
Maximum power loading by consumers:
Resistive consumers include incandescent electric lamps and heaters, for example.
Electric engines and transformers are inductive consumers.
Nominal rating conditions:
■ Ambient temperature: 25 °C
■ Max. height above sea level of the place of installation: 1000 m
AC power supply
Generator
115 V/2~
Nominal power [kVA]
6.0
Resistive consumers
[kVA]
6.0
Inductive consumers [kW]
4.0
Tab. 56 Maximum AC mains load
2.8.3.3 Operational limits
(to EN 60034-22, page 10, table)
Characteristics
Value
Design category
G3
Voltage adjustment range [%]
±5
Static voltage deviation [%]
1
Maximum dynamic voltage drop [%]
–15
Maximum dynamic voltage rise [%]
20
Maximum voltage settling time [ms]
1500
Maximum voltage asymmetry [%]
1
Tab. 57 Generator operating limits
2.8.3.4 Factor of output power reduction
The output power is dependen on installation altitude and ambient temperature.
Output power reduction
Ambient temperature [°C]
40
45
Altitude AMSL [m]
1000
1000
2
Technical Specifications
2.8
Options
22
Operating Manual Portable Rotary Screw Compressor
MOBILAIR M27 PE
No.: 9_9548 22 HCE