■ Clean the electrical components (options)
■ Clean sensitive display instruments
Opening the closed floor pan:
In order to prevent liquid from accumulating inside the machine, the closed floor pan must be
opened.
1. Remove all bung plugs.
2. Clean all bung plugs.
Checking the protective covers are over all plug sockets on the exterior of the machine:
To prevent water ingress, all plug sockets are equipped with self-closing protective covers.
Option symbol
Designation
Position
tc, te
Lighting plug socket
Front side of machine
bb
Coolant preheating plug socket
gb
Electrical consumer plug socket
Tab. 72 Plug sockets on the exterior of the machine
➤ Check that protective covers on the optional plug sockets are all closed correctly.
Covering sensitive components:
1. Cover display instruments.
2. Cover the generator control box (option) with a plastic sheet and close with adhesive tape.
Sensitive display instruments and the generator control box are protected against splash wa‐
ter.
Cleaning the exterior of the machine:
In order to prevent damage when cleaning with a high-pressure washer, the following mini‐
mum distances from the object being cleaned must be maintained:
■ Round jet nozzles: approximately 70 cm
■ Fan jet nozzles: approximately 30 cm
■ Dirt blasters: approximately 30 cm
1. Do not use jet water to clean plug sockets.
2. Do not use jet water to clean the covered generator control box.
3. Deploy the extension pole of the high-pressure washer in order to maintain the necessary dis‐
tance from the object being cleaned.
4. Keep the extension pole of the high-pressure washer in constant motion.
➤ Clean the exterior of the machine with the high-pressure washer.
Result External cleaning by high-pressure washer is complete.
Removing all covers:
1. Remove the cover from the display instruments.
2. Remove the cover from the generator control box (option).
8
Operation
8.4
Cleaning the machine after operation
76
Operating Manual Portable Rotary Screw Compressor
MOBILAIR M27 PE
No.: 9_9548 22 HCE
Option oe