5. Do not direct jet water at the generator (option) or its connector box.
6. Clean non-sensitive components/surfaces inside the machine.
Whilst cleaning, keep the extension pole of the high-pressure washer in constant motion.
Accumulated water in the closed floor pan.
➤ Remove the bung plugs.
➤ Allow the water to drain out.
For information on draining liquids from inside the machine, see chapter 10.9.7.
Removing all covers:
1. Remove the cover from the engine air filter intake opening.
2. Remove the cover from the compressor air filter intake opening.
Result The plastic sheeting and adhesive tape is removed from the interior of the machine.
Cleaning sensitive components:
In the event of heavy contamination of the generator (option), a gentle degreasing cleaning agent
may be used. The cleaning agent must not alter the surfaces of the objects being cleaned.
➤ Clean the following components manually using a cleaning cloth:
■ Generator
■ Generator connector box
■ Solenoid valves
■ Electrical plug-in connections
Sealing the floor pan:
Precondition Any liquid inside the machine has completely drained away.
1. If required, remove any remaining contaminants with a cleaning cloth.
2. Reinsert all bung plugs.
Dispose of dirty covers, adhesive and cleaning cloths in accordance with applicable environ‐
mental protection regulations.
8.5 Operating the options
➤ Comply with all instructions.
8
Operation
8.5
Operating the options
78
Operating Manual Portable Rotary Screw Compressor
MOBILAIR M27 PE
No.: 9_9548 22 HCE
Option oe