A belt that has been replaced may not be used again.
Check the belt tension after running for approximately 15 minutes.
Old belts should be disposed of in accordance with current environmental regulations.
Putting in operation:
1. Replace the belt guard.
2. Reconnect the negative battery terminal.
3. Close the canopy.
10.3.7 Having the antivibration mount checked
Antivibration mounts are elastomer metal elements, that are used, for example, for vibration-damp‐
ened bearing of the drive of construction machines. They consist of two U-profiles that are fastened
to each other through an elastomer.
Fig. 42 Example for antivibration mount of drive engine
1
Antivibration mount
2
Bottom U-profile
3
Elastomer
4
Top U-profile
➤ Have the antivibration mount of the drive engine checked by KAESER SERVICE.
Elastomer of antivibration mount is destroyed or porous.
➤ Have the antivibration mount replaced by KAESER SERVICE.
10.3.8 Battery maintenance
➤ Check the charging system if the battery discharges without reason.
10.3.8.1 Safety
WARNING
Danger of acid burns from escaping electrolyte!
➤ Wear appropriate protective clothing including acid-proof rubber gloves.
➤ Always wear eye and face protection.
➤ Do not tip the battery. Electrolyte may run out of the vent holes.
➤ Work with caution.
10 Maintenance
10.3 Drive engine maintenance
No.: 9_9548 22 HCE
Operating Manual Portable Rotary Screw Compressor
MOBILAIR M27 PE
119