HP P2000 G3 MSA System CLI Reference Guide 521
Glossary
CAPI
Configuration Application Programming Interface. The proprietary protocol used for
communication between the Storage Controller and the Management Controller in a
controller module. CAPI is always enabled.
CHAP
Challenge-Handshake Authentication Protocol.
chunk size
The amount of contiguous data that is written to a vdisk member before moving to the next
member of the vdisk.
compatible disk
A disk that has enough capacity to replace a failed disk and is the same type (SAS or
SATA).
dedicated spare
A disk that is reserved for use by a specific vdisk to replace a failed disk. See compatible
disk.
default mapping
Host-access settings that are configured when a volume is created, and that apply to all
hosts that are not explicitly mapped to that volume using different settings. See also explicit
mapping and masking.
drive spin down (DSD)
A power-saving feature that monitors disk activity in the storage system and spins down
inactive SAS and SATA disks, based on user-selectable policies.
DRM
Disaster recovery management. Storage-system firmware features that, when the Site
Replication Adapter (SRA) feature is enabled, support the use of VMware’s Site Recovery
Manager to automate disaster-recovery failover and failback tasks. See also SRA.
dual-port disk
A disk that is connected to both controllers so its data path is fault-tolerant.
dynamic spare
An available compatible disk that is automatically assigned, if the dynamic spares option is
enabled, to replace a failed disk in a redundant vdisk. See compatible disk.
EC
Expander Controller. The processor (located in the SAS expander in each controller module
and expansion module) that controls the SAS expander and provides SES functionality. See
also EMP.
EMP
Enclosure management processor. An EC subsystem that provides SES data such as
temperature, power supply and fan status, and the presence or absence of disks.
explicit mapping
Access settings for a host to a volume that override the volume’s default mapping. See also
default mapping and masking.
FC
Fibre Channel interface protocol.
FRU
Field-replaceable unit.
global spare
A disk that is reserved for use by any redundant vdisk to replace a failed disk. See
compatible disk.
host
An external port that the storage system is attached to. The external port may be a port in
an I/O adapter in a server, or a port in a network switch.
image ID
A globally unique serial number that identifies the point-in-time image source for a volume.
All volumes that have identical image IDs have identical data content, whether they be
snapshots or stand-alone volumes.
IOM
Input/output module, which can be either a controller module or an expansion module.
IQN
iSCSI Qualified Name.
iSCSI
Internet SCSI interface protocol.
iSNS
Internet Storage Name Service.
jumbo frame
In an iSCSI network, a frame that can contain 9000 bytes for large data transfers. A normal
frame can contain 1500 bytes.
leftover
The state of a disk that has been automatically excluded from a vdisk, and is no longer
needed by the vdisk after the vdisk is reconstructed.
loop
Fibre Channel Arbitrated Loop (FC-AL) topology.
Summary of Contents for P2000 G3
Page 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Page 14: ...14 About this guide ...
Page 30: ...30 Categorical list of commands ...