390 XML API basetype properties
owner
string
Current owner, which is either the preferred owner during normal operation or
the partner controller when the preferred owner is offline.
•
A
: Controller A.
•
B
: Controller B.
owner-numeric
string
Numeric equivalents for
owner
values.
•
0: B
•
1: A
index
uint32
For internal use only.
rpm
uint32
Disk RPM in units of1000, as specified by the vendor.
size
string
Disk capacity, formatted to use the current base, precision, and units.
size-numeric
string
Unformatted
size
value in 512-byte blocks.
transfer-rate
string
Disk data-transfer rate in Gbit/second (Gbps).
•
1.5
•
3.0
•
6.0
Some 6-Gbps disks might not consistently support a 6-Gbps transfer rate. If this
happens, the P2000 controller automatically adjusts transfers to those disks to
3 Gbps, increasing reliability and reducing error messages with little impact on
system performance. This rate adjustment persists until the controller is restarted
or power-cycled.
transfer-rate-
numeric
string
For internal use only.
attributes
string
Shows which controller a single-ported disk is connected to.
•
A
: Controller A.
•
B
: Controller B.
attributes-
numeric
string
For internal use only.
virtual-disk-
serial
string
Serial number of the disk's vdisk, if any.
enclosure-wwn
string
Enclosure WWN.
status
string
Disk status.
•
Up
: The disk is present and is properly communicating with the expander.
•
Spun Down
: The disk is present and has been spun down by the drive spin
down feature.
•
Warning
: The disk is present but the system is having communication
problems with the disk LED processor. For disk and midplane types where
this processor also controls power to the disk, power-on failure will result in
Error
status.
•
Error
: The disk is present but is not detected by the expander.
•
Unknown
: Initial status when the disk is first detected or powered on.
•
Not Present
: The disk slot indicates that no disk is present.
usage
string
Not applicable.
operation
string
Not applicable.
Table 26
drives properties (continued)
Name
Type
Description
Summary of Contents for P2000 G3
Page 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Page 14: ...14 About this guide ...
Page 30: ...30 Categorical list of commands ...
Page 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...
Page 294: ...294 Alphabetical list of commands See also set volume set vdisk ...
Page 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...
Page 524: ...524 Glossary ...
Page 532: ...532 Index ...