HP P2000 G3 MSA System CLI Reference Guide 149
Example
Set the system to send an email from
to both
and
when a non-Informational event occurs,
and to send an email with attached logs to
when logs need to
be transferred:
# set email-parameters server 10.1.1.10 sender RAIDsystem domain mydomain.com
notification-level warn include-logs enabled email-list
[email protected],[email protected],,[email protected]
Info: Set Email Address 1 to: [email protected] ([email protected])
Info: Set Email Address 2 to: [email protected] ([email protected])
Info: Set Email Address 3 to:
Info: Set Email Address 4 to: [email protected]
([email protected])
Info: Set Email Server Name to: 10.1.1.10 (10.1.1.10)
Info: Set Email Domain Name to: mydomain.com (mydomain.com)
Info: Set Email Notification Level to: warn (mydomain.com)
Info: Set Email Sender Name to: RAIDsystem (RAIDsystem)
Info: Set Email Include Logs: enabled (enabled)
Success: Command completed successfully. (2012-01-21 15:07:46)