HP P2000 G3 MSA System CLI Reference Guide 369
dash-level
string
FRU template revision number.
fru-shortname
string
FRU short description.
mfg-date
string
Date and time, in the format
year-month-day hour
:
minutes
:
seconds
(UTC), when the controller's PCBA was programmed.
mfg-date-
numeric
string
Unformatted
mfg-date
value.
mfg-location
string
City, state/province, and country where the FRU was manufactured.
mfg-vendor-id
string
JEDEC ID of the FRU manufacturer.
health
string
•
OK
•
Fault
•
Unknown
health-numeric
string
Numeric equivalents for
health
values.
•
0: OK
•
2: Fault
•
3: Unknown
health-reason
string
If Health is not
OK
, the reason for the health state.
health-
recommendation
string
If Health is not
OK
, the recommended actions to take to resolve the health issue.
position
string
Position of the controller in the enclosure.
•
Top
: The controller is in the top slot.
•
Bottom
: The controller is in the bottom slot.
position-
numeric
string
Numeric equivalents for
position
values.
•
0: Top
•
1: Bottom
phy-isolation
string
Shows whether the automatic disabling of SAS expander PHYs having high error
counts is enabled or disabled for this controller.
•
Enabled
: PHY fault isolation is enabled. This is the default.
•
Disabled
: PHY fault isolation is disabled.
phy-isolation-
numeric
string
Numeric equivalents for
phy-isolation
values.
•
0: Enabled
•
1: Disabled
redundancy-mode
string
The system’s operating mode, also called the cache redundancy mode.
•
Active-Active ULP
: Both controllers are active using ULP (Unified LUN
Presentation). Data for volumes configured to use write-back cache is
automatically mirrored between the two controllers to provide fault
tolerance.
•
Single Controller
: The enclosure contains a single controller.
•
Single Controller
: The enclosure contains a single controller.
•
Fail Over
: Operation has failed over to one controller because its partner
is not operational. The system has lost redundancy.
•
Down
: Both controllers are not operational.
Table 19
controllers properties (continued)
Name
Type
Description
Summary of Contents for P2000 G3
Page 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Page 14: ...14 About this guide ...
Page 30: ...30 Categorical list of commands ...
Page 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...
Page 294: ...294 Alphabetical list of commands See also set volume set vdisk ...
Page 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...
Page 524: ...524 Glossary ...
Page 532: ...532 Index ...