HP P2000 G3 MSA System CLI Reference Guide 461
Example
# show expander-status
...
<OBJECT basetype="sas-status-controller-a" name="enclosure-id" oid="1" format="rows">
<PROPERTY name="enclosure-id" type="uint32">1</PROPERTY>
<PROPERTY name="controller" type="string">A</PROPERTY>
<PROPERTY name="controller-numeric" type="string">1</PROPERTY>
<PROPERTY name="phy" type="uint32">0</PROPERTY>
<PROPERTY name="type" type="string">Drive</PROPERTY>
<PROPERTY name="type-numeric" type="string">1</PROPERTY>
<PROPERTY name="status" type="string">Enabled - Healthy</PROPERTY>
<PROPERTY name="status-numeric" type="string">1</PROPERTY>
<PROPERTY name="elem-status" type="string">OK</PROPERTY>
<PROPERTY name="elem-status-numeric" type="string">1</PROPERTY>
<PROPERTY name="elem-disabled" type="string">Enabled</PROPERTY>
<PROPERTY name="elem-disabled-numeric" type="string">0</PROPERTY>
<PROPERTY name="elem-reason" type="string"></PROPERTY>
<PROPERTY name="elem-reason-numeric" type="string">0</PROPERTY>
<PROPERTY name="change-counter" type="uint32">00000003</PROPERTY>
<PROPERTY name="code-violations" type="uint32">00000000</PROPERTY>
<PROPERTY name="disparity-errors" type="uint32">00000000</PROPERTY>
<PROPERTY name="crc-errors" type="uint32">00000000</PROPERTY>
elem-reason-
numeric
string
Numeric equivalents for
elem-reason
values.
•
0:
(blank)
•
32769: Error count interrupts
•
32770: Externally disabled
•
32771: PHY control
•
32772: Not ready
•
32774: Drive removed
•
32775: Unused - disabled by default
•
32776: Excessive PHY changes
change-counter
uint32
Number of times the PHY originated a BROADCAST (CHANGE). A
BROADCAST (CHANGE) is sent if doubleword synchronization is lost or at the
end of a Link Reset sequence.
code-violations
uint32
Number of times the PHY received an unrecognized or unexpected signal.
disparity-
errors
uint32
Number of doublewords containing running disparity errors that have been
received by the PHY, not including those received during Link Reset sequences. A
running disparity error occurs when positive and negative values in a signal
don’t alternate.
crc-errors
uint32
In a sequence of SAS transfers (frames), the data is protected by a cyclic
redundancy check (CRC) value. The
crc-errors
value specifies the number of
times the computed CRC does not match the CRC stored in the frame, which
indicates that the frame might have been corrupted in transit.
conn-crc-errors
uint32
Number of times the lane between two expanders experienced a
communication error.
lost-dwords
uint32
Number of times the PHY has lost doubleword synchronization and restarted the
Link Reset sequence.
invalid-dwords
uint32
Number of invalid doublewords that have been received by the PHY, not
including those received during Link Reset sequences.
reset-error-
counter
uint32
Number of times the expander performed a reset of error counters.
flag-bits
uint32
PHY status flag bits.
Table 67
sas-status-controller-a properties (continued)
Name
Type
Description
Summary of Contents for P2000 G3
Page 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Page 14: ...14 About this guide ...
Page 30: ...30 Categorical list of commands ...
Page 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...
Page 294: ...294 Alphabetical list of commands See also set volume set vdisk ...
Page 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...
Page 524: ...524 Glossary ...
Page 532: ...532 Index ...