486 XML API basetype properties
time-settings-table
Properties
Example
# show controller-date
...
<OBJECT basetype="time-settings-table" name="time-settings-table" oid="1">
<PROPERTY name="date-time" type="string">2012-02-16 13:12:28</PROPERTY>
<PROPERTY name="date-time-numeric" type="string">1329397948</PROPERTY>
<PROPERTY name="time-zone-offset" type="string">-07:00</PROPERTY>
<PROPERTY name="ntp-state" type="string">Enabled</PROPERTY>
<PROPERTY name="ntp-address" type="string">10.64.10.1</PROPERTY>
</OBJECT>
...
Table 82
time-settings-table properties
Name
Type
Description
date-time
string
Date and time, in the format
year-month-day hour
:
minutes
:
seconds
(UTC), reported by the controller being accessed.
date-time-
numeric
string
Unformatted
date-time
value.
time-zone-
offset
string
The system's time zone as an offset in hours and minutes from UTC. This is shown
only if NTP is enabled.
ntp-state
string
Shows whether Network Time Protocol (NTP) is in use.
•
activated
: NTP is enabled.
•
deactivated
: NTP is disabled. This is the default.
ntp-address
string
NTP server IP address, or 0.0.0.0 if not set.
Summary of Contents for P2000 G3
Page 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Page 14: ...14 About this guide ...
Page 30: ...30 Categorical list of commands ...
Page 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...
Page 294: ...294 Alphabetical list of commands See also set volume set vdisk ...
Page 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...
Page 524: ...524 Glossary ...
Page 532: ...532 Index ...