368 XML API basetype properties
failed-over
string
Indicates whether the partner controller has failed over to this controller.
•
No
: The partner controller has not failed over to this controller.
•
Yes
: The partner controller has either failed or been shut down, and its
responsibilities have been taken over by this controller. There will be a delay
between the time that the value of
Status
becomes
Down
for one controller
and the time that the value of
Failed Over to This Controller
becomes
Yes
for the other controller. This time period is the time that it takes
for a controller to take over the responsibilities of its partner.
failed-over-
numeric
string
Numeric equivalents for
failed-over
values.
•
0: No
•
1: Yes
fail-over-
reason
string
If
failed-over
is
Yes
, a reason for the failover appears; otherwise,
Not
applicable
appears.
fail-over-
reason-numeric
string
Numeric equivalents for
fail-over-reason
values.
sc-fw
string
Storage Controller firmware version.
vendor
string
Controller manufacturer.
model
string
Controller model.
sc-cpu-type
string
Storage Controller processor type.
sc-cpu-speed
sint32
Storage Controller processor speed.
internal-
serial-number
string
Internal serial number of the controller.
cache-lock
string
Shows whether hosts are prevented from using the
SCSI MODE SELECT
command to change the storage system's write-back cache setting.
•
No
: Hosts are permitted to disable write-back cache.
•
Yes
: Hosts are prevented from disabling write-back cache. This is the
default.
cache-lock-
numeric
string
Numeric equivalents for
cache-lock
values.
•
0: No
•
1: Yes
write-policy
string
The current, system-wide cache policy as determined by auto-write-through
(AWT) logic. This value is not settable by users. If an AWT trigger condition
(such as a CompactFlash failure) is met, the cache policy for all volumes
changes to write-through, overriding the volume-specific settings. When the
problem is corrected, the cache policy reverts to the value configured for each
individual volume.
•
write-back
: This is the normal state.
•
write-through
•
Not up
: The controller is not up.
write-policy-
numeric
string
Numeric equivalents for
write-policy
values.
•
0
:
write-back
•
1
:
write-through
•
2
: Not up.
description
string
FRU long description.
part-number
string
Part number for the FRU.
revision
string
Hardware revision level for the FRU.
Table 19
controllers properties (continued)
Name
Type
Description
Summary of Contents for P2000 G3
Page 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Page 14: ...14 About this guide ...
Page 30: ...30 Categorical list of commands ...
Page 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...
Page 294: ...294 Alphabetical list of commands See also set volume set vdisk ...
Page 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...
Page 524: ...524 Glossary ...
Page 532: ...532 Index ...