HP P2000 G3 MSA System CLI Reference Guide 383
Example
# show disk-statistics
...
<OBJECT basetype="disk-statistics" name="disk-statistics" oid="1" format="rows">
<PROPERTY name="durable-id" type="string">disk_1.1</PROPERTY>
<PROPERTY name="serial-number" key="true" type="string">
SN
</PROPERTY>
<PROPERTY name="bytes-per-second" units="B" type="string">0B</PROPERTY>
<PROPERTY name="bytes-per-second-numeric" type="string">0</PROPERTY>
<PROPERTY name="iops" type="uint32">0</PROPERTY>
<PROPERTY name="number-of-reads" type="uint64">560748</PROPERTY>
<PROPERTY name="number-of-writes" type="uint64">141124</PROPERTY>
<PROPERTY name="data-read" units="GB" type="string">35.03GB</PROPERTY>
<PROPERTY name="data-read-numeric" type="string">35038771200</PROPERTY>
<PROPERTY name="data-written" units="GB" type="string">508.20GB</PROPERTY>
<PROPERTY name="data-written-numeric" type="string">508206256640</PROPERTY>
<PROPERTY name="queue-depth" type="uint32">0</PROPERTY>
<PROPERTY name="reset-time" type="string">2012-02-13 12:45:16</PROPERTY>
<PROPERTY name="reset-time-numeric" type="string">1329137116</PROPERTY>
<PROPERTY name="start-sample-time" type="string">2012-02-24 12:47:34</PROPERTY>
<PROPERTY name="start-sample-time-numeric" type="string">1330087654</PROPERTY>
<PROPERTY name="stop-sample-time" type="string">2012-02-29 10:19:57</PROPERTY>
<PROPERTY name="stop-sample-time-numeric" type="string">1330510797</PROPERTY>
<PROPERTY name="smart-count-1" type="uint32">0</PROPERTY>
<PROPERTY name="io-timeout-count-1" type="uint32">0</PROPERTY>
<PROPERTY name="no-response-count-1" type="uint32">0</PROPERTY>
<PROPERTY name="spinup-retry-count-1" type="uint32">0</PROPERTY>
number-of-
media-errors-1
uint32
For port 1, the number of media errors generated by the disk, as specified by its
manufacturer.
number-of-
nonmedia-
errors-1
uint32
For port 1, the number of other errors generated by the storage system, or
generated by the disk and not categorized as media errors.
number-of-
block-
reassigns-1
uint32
For port 1, the number of times blocks were reassigned to alternate locations.
number-of-bad-
blocks-1
uint32
For port 1, the number of bad blocks encountered.
smart-count-2
uint32
For port 2, the number of pending I/O operations currently being serviced.
io-timeout-
count-2
uint32
For port 2, the number of SMART events recorded.
no-response-
count-2
uint32
For port 2, the number of timeouts accessing the disk.
spinup-retry-
count-2
uint32
For port 2, the number of times the disk did not respond.
number-of-
media-errors-2
uint32
For port 2, the number of attempts by the storage system to spin up the disk.
number-of-
nonmedia-
errors-2
uint32
For port 2, the number of media errors generated by the disk, as specified by its
manufacturer.
number-of-
block-
reassigns-2
uint32
For port 2, the number of other errors generated by the storage system, or
generated by the disk and not categorized as media errors.
number-of-bad-
blocks-2
uint32
For port 2, the number of times blocks were reassigned to alternate locations.
Table 23
disk-statistics properties (continued)
Name
Type
Description
Summary of Contents for P2000 G3
Page 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Page 14: ...14 About this guide ...
Page 30: ...30 Categorical list of commands ...
Page 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...
Page 294: ...294 Alphabetical list of commands See also set volume set vdisk ...
Page 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...
Page 524: ...524 Glossary ...
Page 532: ...532 Index ...