156 Alphabetical list of commands
gateway
address
Optional. For iSCSI, the port gateway address.
ip
address
Optional. For iSCSI, the port IP address. Ensure that each iSCSI host port in the storage system is
assigned a different IP address.
iscsi-ip-version ipv4|ipv6
Specifies whether to use IP version 4 (IPv4) or 6 (IPv6) for addressing controller iSCSI ports.
•
ipv4
: Lets you specify addresses in dot-decimal format, where the four octets of the address use
decimal values without leading zeroes and the octets are separated by a period; for example,
10.132.2.205
. This option is the default.
•
ipv6
: Lets you specify addresses using eight groups of four hexadecimal digits, where the
groups are separated by a colon. All groups must be specified. For example,
0000:0000:0000:0000:0000:0000:0A90:3442.
netmask
address
Optional. For iSCSI, the port netmask address.
noprompt
Optional in console format; required for XML API format. Suppresses the confirmation prompt, which
requires a yes or no response. Specifying this parameter allows the command to proceed without
user interaction.
ports
ports
|all
Optional. Specific host port numbers or all ports. For port syntax, see
Command syntax
on page 22.
prompt yes|no|expert
Optional. Specifies an automatic response to the confirmation prompt:
•
yes
: Allow the command to proceed.
•
no
: Cancel the command.
•
expert
: Allow the command to proceed.
If this parameter is omitted, you must manually reply to the prompt.
speed 2g|4g|8g|auto
Optional. For FC, sets a forced link speed in Gbit/sec or lets the speed be auto-negotiated (
auto
).
Because a speed mismatch prevents communication between the port and host, set a speed only if
you need to force the port to use a known speed for testing, or you need to specify a mutually
supported speed for more than two FC devices connected in an arbitrated loop.
Example
On a system with FC ports, set the link speed to 8 Gbit/sec for ports A1 and B1:
# set host-parameters speed 8g ports a1,b1
WARNING: This change will take effect immediately. Changes may affect access to
data. Are you sure?
yes
Success: Command completed successfully. - The host parameters were changed
successfully. (2012-01-21 15:42:52)
On a system with FC ports, set controller A ports to request loop ID 14 and controller B ports to use
soft target addressing, and suppress the confirmation prompt:
# set host-parameters fibre-loop-id 14,soft noprompt
Info: Changes to FC loop IDs will not take effect until the affected Storage
Controller is rebooted.
Success: Command completed successfully. - The host parameters were changed
successfully. (2012-01-21 15:45:00)
Summary of Contents for P2000 G3
Page 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Page 14: ...14 About this guide ...
Page 30: ...30 Categorical list of commands ...
Page 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...
Page 294: ...294 Alphabetical list of commands See also set volume set vdisk ...
Page 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...
Page 524: ...524 Glossary ...
Page 532: ...532 Index ...