Scanner Maintenance
Drive belt system
WARNING
:
Injury can occur. The head can move without
warning. Keep hands, hair, and clothing clear of
belts, pulleys, and other moving parts. Stand clear
of moving heads.
12.
Shut the Motor Power keyswitch off.
13.
Reinstall the beam covers as described in Subsection 9.1.7.
14.
Run a profile correction for the sensors that need it (Refer to the
Da
Vinci System Installation and Setup Manual
Honeywell p/n
46018200).
15.
Record the maintenance in the scanner logbook.
9.6.4. Adjusting head MD alignment and gap
To adjust the head machine direction (MD) alignment and gap:
1.
Scan the heads to the offsheet position at the cable end of the
scanner.
2.
Turn off the Motor Power keyswitch.
WARNING
:
To perform any maintenance, troubleshooting, or
replacement of components, ensure that power is
disabled at the breaker.
WARNING
:
If the head air gap of a sensor containing a
radioactive or X-ray source is changed from its
original size(for example, from a 0.4-in. gap to a
0.5-in. gap), regulations require that a Radiation
Survey be performed and documented before the
sensor is put into use. This survey must be
performed by an individual specifically licensed
to perform this operation.
p/n 6510020208
10/18/07
9-23
Summary of Contents for 4022
Page 1: ...Precision Platform 4022 Scanner System Manual 6510020208 ...
Page 2: ......
Page 3: ...Precision Platform 4022 Scanner October 2007 ...
Page 22: ......
Page 72: ......
Page 94: ......
Page 126: ......
Page 162: ......
Page 170: ......
Page 234: ......
Page 239: ...Glossary p n 6510020208 10 18 07 11 5 VIO Virtual Input Output ...