Scanner Maintenance
Power tracks
9.3.2. Replace upper and lower power track
Life expectancy of the power tracks varies based on these factors:
•
Scan speed
•
Scanner environment
•
Scanner air purge
•
Regular Power track maintenance of the ribbon cable tension
See the maintenance schedule in Chapter 8 for suggested maintenance
tasks and their intervals.
WARNING
:
To perform any maintenance, troubleshooting, or
replacement of components, ensure that power is
disabled at the breaker.
1.
Push heads to the Distant End of the scanner (opposite the Cable
End).
2.
Remove the beam covers.
i
N
OTE
:
Before completely removing the power track from
the scanner take measurements for the drop cables
and hoses to compare with the replacement power
track.
3.
Remove the head cover and disconnect the connectors from the
head termination board.
4.
Remove the head clamp screws that hold the power track to the
head.
5.
Carefully pull the cables and connectors through the head and let
them hang.
6.
Measure the drop length of the cables and hoses and compare to
the new power track.