Cable End Electrical Assemblies and Precision Measurement Processor
Remote 4604-02 PMP
p/n 6510020208
10/18/07
6-27
Table 6-7 Logic PCB Jumpers, LEDs, and Fuses
Jumpers: Logic
PCB
(4022 -30, -31)
W1
A: MXOpen, B: Da Vinci
W2
A: MXOpen, B: Da Vinci
TB1
Head Over Temp DISABLED
(connect TB1-1 to TB1-2)
LED
Indicators:
Logic PCB
(4022 -30, -31)
DS1
Encoder phase A out
DS2
Encoder phase B out
DS3
Head Over Temperature
DS4 Motor
forward
DS5 Motor
reverse
DS6
Shutter 24V (lamps good)
Fuse Logic
PCB
(4022 -30, -31)
F1
1A - Encoder phase B out
F2
1A - Encoder phase A out
F3
1A - To “Over temp” contact
IN
F4
1A - 24V relay
F5
1.5A - Red lamp IN
F6
1A - Switched 24V to BW
shutter (Sx9, 12)
F7
1.5A – Spare
F8
1A – Spare
6.4. Remote 4604-02 PMP
Both the 4022-31 Precision Platform scanner and 4022-40 scanner for Wire
Calender applications use the same 4604-02 PMP. The 4022-30 scanner is
designed for existing MXOpen systems and does not require a PMP. See
Chapter 7 for more information on the 4022-40 scanner.