90
-
Connection
①
Remove the jumpers of P and P1 terminals.
②
Connect DC reactor to Terminals P and P1 as shown in the following
diagram:
DC Reactor
Note: HLP inverter of above
37KW has connectors. The
inverter of below 37KW must
not be connected with it.
The f unction of DC reactor is to restrict the AC component stacked with DC
reactor to a specified value to suppress the mains harmonics and improve the
power factor of the inverter.
2) AC Reactors Disposition
AC Reactor Model Matched Power
(W)
Rated Current
(A)
Inductance
(mH)
HKSG2-24
11
24
0.52
HKSG2-34
15
34
0.397
HKSG2-38
18.5
38
0.352
HKSG2-50
22
50
0.26
HKSG2-60
30
60
0.24
HKSG2-75
37
75
0.235
HKSG2-91
45
91
0.17
HKSG2-112
55
112
0.16
HKSG2-150
75
150
0.112
HKSG2-180
90
180
0.10
HKSG2-220
110
220
0.09
HKSG2-265
132
265
0.08
HKSG2-300
160
300
0.07
HKSG2-360
200 (185)
360
0.06
HKSG2-400
220
400
0.05
HKSG2-560
280
560
0.03
HKSG2-640
315
640
0.0215
HKSG2-700
345
700
0.019
HKSG2-750
375
750
0.017
HKSG2-800
400
800
0.015
HKSG2-860
415
860
0.012
Summary of Contents for HLP-A Series
Page 1: ......
Page 2: ...HLP A Series...
Page 3: ......
Page 27: ...HLP A Series HLP A Series 22 1 Good 2 Good 3 Not good...
Page 69: ...HLP A Series HLP A Series 64 The following is the block diagram of multi pumps operation...
Page 106: ...HLP A Series HLP A Series 101 HLPA05D523B HLPA07D523B Unit mm HLPA05D543B HLPA07D543B Unit mm...
Page 117: ......