HLP-A Series
HLP-A Series
-
89
-
3) DC reactors
It is necessary to install a DC reactor when the capacity of power supply is
more than 1000 KVA or the mains power capacity is higher than the rated
capacity of the inverter. A DC reactor is also needed for the case with higher
demand on the improvement of power factor of power supply. This DC
reactor can be used together with an AC reactor to achieve the obvious effect
of decreasing high-order harmonic at input. If it is necessary to install a DC
reactor please contact the local distributor.
2. Disposition
1) DC Reactors Disposition
DC Reactor Model Matched Power
(W)
Rated Current
(A)
Inductance
(mH)
DCL-37
37
100
0.7
DCL-45
45
120
0.58
DCL-55
55
146
0.47
DCL-75
75
200
0.35
DCL-90
90
238
0.29
DCL-110
110
291
0.24
DCL-132
132
326
0.215
DCL-160
160
395
0.177
DCL-200
200
494
0.142
DCL-220
220
557
0.126
DCL-280
280
700
0.10
DCL-300
300
800
0.08
DCL-315
315
800
0.08
DCL-345
345
660
0.07
DCL-375
375
715
0.064
DCL-400
400
765
0.058
DCL-415
415
795
0.053