HLP-A Series
HLP-A Series
-
94
-
Parameter setting:
CD033=1 CD034=1 CD066=50 CD068=50
CD067=1 CD069=0 CD070=1
4. Internal Control 8 Speed Run
A curve as shown in the following diagram is established. Internal control
8-speed run will stop after running for one cycle.
Parameter setting:
CD076=4 CD000=30 CD080=50 CD081=30
CD082=20 CD083=40 CD084=10 CD085=35
CD086=15 CD078=36
CD077=0
CD012=5
CD013=5
CD033=1
CD079=0
CD050=1
CD087-CD094=15
Note:
1. The running time of each speed is set by CD087-CD094=15.
2. Auto cycling CD077=1
3. After the running command is given it will run with the set curve for one
cycle and stop.