HLP-A Series
HLP-A Series
-
60
-
0: For. 1: Rev.
Main Speed (CD000) For.
Frequency 1 (CD080) Rev.
Frequency 2 (CD081) For.
Frequency 3 (CD082) Rev.
Frequency 4 (CD083) For.
Frequency 5 (CD084) For.
Frequency 6 (CD085) Rev.
Frequency 7 (CD086) For.
The parameter value 01001010 is converted to a decimal value:
1×2
6
+1×2
3
+1×2
1
=64+8+2=74
Then CD078=74
CD079 PLC Ramp Time
Set Range: 0~65535S Unit: 1S Factory Setting: 0
This parameter is only valid when CD076 is set to 4.
This parameter is set to determine the ramp time values for Step 1~4 of the
internal control multi-speed. The setting method is as follows:
①
Determine each Ramp Time in the binary 2 bit mode
Bit1
Bit0
Ramp Time
0
0
Ramp Time 1 CD012, CD013
0
1
Ramp Time 2 CD014, CD015
1
0
Ramp Time 3 CD016, CD017
1
1
Ramp Time 4 CD018, CD019
②
Determine the Ramp time of each speed step in the binary 16 bit mode
Step 8
Step 7
Step 6
Step 5
Step 4
Step 3
Step 2
Step 1
t8
t7
t6
t5
t4
t3
t2
t1
0
0
0
0
0
0
0
0
0
1
1
0
0
0
1
1
t1 Select Ramp Time 4
t2 Select Ramp Time 1
t3 Select Ramp Time 3 The setting value:
t4 Select Ramp Time 2 1×2
0
+1×2
1
+1×2
5
+1×2
6
=99
Summary of Contents for HLP-A Series
Page 1: ......
Page 2: ...HLP A Series...
Page 3: ......
Page 27: ...HLP A Series HLP A Series 22 1 Good 2 Good 3 Not good...
Page 69: ...HLP A Series HLP A Series 64 The following is the block diagram of multi pumps operation...
Page 106: ...HLP A Series HLP A Series 101 HLPA05D523B HLPA07D523B Unit mm HLPA05D543B HLPA07D543B Unit mm...
Page 117: ......