76
-
(
5
)
8E1 For RTU C D162=4
(
6
)
8O1 For RTU C D162=5
3
:
Communication Document Formats
3.1 ASCII Mode
Communication Document Forms
STX
“ : ”
(3AH)
ADDR FUNC
LEN
DATA
(n-1)
....
DATA
0
CRC
END
CR(0DH)
LF(0AH)
(1) STX: Starting unit “ : ” (3AH)
(2) ADDR communication address,8-bit data is composed of
two ASC II byte.
00: Broadcast mode is MODBUS
01~250: Address of the corresponding inverters.
(3) FUNC: Function code 8-bit data is composed of two ASC II byte.
01: FUNC READ, Read the data of f unction code
02: FUNC WRIT, write the data of f unction code
03: Write control data
04: Read control status data
05: Write inverter frequency data
06: Reserved
07: Reserved
08: Loop test
a: Read f unction code data
Format:
ADDR 01 LEN FUNC Data
ADDR=0 means no answer
ADDR≠0 means a reply from inverter of this address
When inverter reply normal, the format as follows~
ADDR 01 LEN FUNC Data