10. SOFTWARE RAID1
10-35
Table 10-1 Error Messages from the Software RAID1 construction utility (2/2)
No. Error
message
Description
Corrective
action
7
Disk is not mounted.
Rebuild or a consistency check is
selected when two HDDs are not
mounted.
Make sure two HDDs are mounted, and then start
rebuild or a consistency check.
8
Disk access error on
HDD#X.
Access to the RAID1 configuration
information of the HDD#X (X is an
HDD number) failed.
Replace the failed HDD, and then start rebuild.
9
RAID condition is not
correct.
The configuration or status of the array
is not normal.
Set the status of the software RAID1 to be normal
(that is, Array Status on the status display for
RAID1 is “OPTIMAL” or “OPTIMAL (MEDIA
ERROR)”), and then start a consistency check.
10
Cannot execute the Prepare
For Restore operation.
The backup restoration preparation
function cannon be executed.
Check the status of installation of the HDDs.
Make sure both HDDs are installed, and then start
the backup restoration preparation function.