![Hioki MR8740 Instruction Manual Download Page 357](http://html1.mh-extra.com/html/hioki/mr8740/mr8740_instruction-manual_2137324357.webp)
17.4 File Specifications
345
Chapte
r 17 S
pecifications
16
17
Data Saving
Data Loading
Others
17.4 File Specifications
Supported storage media
USB memory stick, Internal RAM, LAN (Model 9333 LAN Communicator)
Saved data
MR8740: Setting data, measurement data, screen image, print image
MR8741: Setting data, measurement data, screen image, print image,
waveform evaluation conditions, waveform evaluation areas
Saving types
• Setting data (.SET) (Only setting configurations can be saved to internal RAM)
• Measurement data
Binary format (.MEM, .REC, .FFT), Text format (.TXT)
• Index , Memory division (.SEQ)
,
division save (.IDX)
• Screen image (.BMP)
• Print image (.BMP)
• Waveform evaluation conditions (.ARE) *Evaluation area + Saving settings (MR8741 only)
• Waveform evaluation area (.BMP) *Saving of evaluation area (MR8741 only)
Arbitrary waveform data (.WFG) (when Model U8793 is installed)
• Generation program data (.FGP) (when Model U8793 is installed)
• Pulse pattern data (.PLS) (when Model MR8791 is installed)
File name entry
Alphanumerics and Japanese
Saving range
Whole range, or between A/B cursors
Data thinning save
When saved in text format
OFF, 1/2, 1/5, 1/10, 1/20, 1/50, 1/100, 1/200, 1/500, 1/1000
Division save
When saved in binary format
16 MB, 32 MB, 64 MB
Duplicate file name handling
Auto:
If a file with the same name exists, saves the file, adding a 4-digit number at the begin-
ning of the file name.
Serial:
Saves the file, adding a 4-digit number at the beginning of the file name.
Overwrite: If a file with the same name exists, overwrites the file.
Error:
If a file with the same name exists, an error message will be displayed.
Selection of blocks to be
saved
Saves the selected blocks when dividing the memory
Selection of channels to be
saved
Selects the channels to save (measurement data, calculation data)
Supported storage media
USB memory stick, Internal RAM
Loadable data types
MR8740: Setting data, measurement data, analysis data
MR8741: Setting data, measurement data, analysis data,
waveform evaluation conditions, waveform evaluation area
Loadable data formats
• Setting data (.SET) (Setting configurations can only be saved to internal RAM)
• Measurement data
Binary format (.MEM, .REC, .FFT)
• Index memory division (.SEQ), division save (.IDX)
• Waveform evaluation conditions (.ARE)
Evaluation area + Loading a setting configurations (MR8741 only)
• Evaluation area (.BMP)
Loading a evaluation area (MR8741 only)
• Arbitrary waveform data (when Model U8793 is installed)
• Generation program data (.FGP) (when Model U8793 is installed)
• Pulse pattern data (.PLS) (when Model MR8791 is installed)
Loading method
New
Display file information
Included
Delete data
Single or multiple file selections
Sort files
By name, date, size, extension
Ascending order, descending order
Rename file
Included
Directory
Create, rename and delete
Copy file
Copy to other media
One-Touch saving
The saving format and data specified in advance can be saved with a single action
(One-Touch saving via
SAVE
key or a mouse click).
Summary of Contents for MR8740
Page 2: ......
Page 12: ...Contents x ...
Page 26: ...Operating Precautions 14 ...
Page 128: ...5 5 Miscellaneous Printing Functions 116 ...
Page 196: ...7 12 Setting Output Waveform Parameters 184 ...
Page 234: ...9 5 Numerical Calculation Type and Description 222 ...
Page 248: ...10 3 Waveform Calculation Operators and Results 236 ...
Page 302: ...12 8 FFT Analysis Modes 290 ...
Page 316: ...13 6 Editor Command Details 304 ...
Page 416: ...Appendix 4 FFT Definitions A26 ...
Page 421: ......
Page 422: ......
Page 423: ......
Page 424: ......