![Hioki MR8740 Instruction Manual Download Page 252](http://html1.mh-extra.com/html/hioki/mr8740/mr8740_instruction-manual_2137324252.webp)
11.2 Display Settings
240
11.2 Display Settings
Procedure
To open the screen: Right-click and select
[STATUS]
→
[Memory Div]
sheet
1
To display any block on the Waveform screen
Set the display blocks
Set after measurement is complete.(This can also be set on the
Waveform screen (p.134).)
Move the flashing cursor to the
[Display Block]
item.
Set the number of blocks to display on the Waveform screen.
2
To display multiple blocks as overlaid waveforms
Enable the Reference Block function
Move the flashing cursor to the
[Ref Block]
item.
Select
[On]
.
3
(When Reference Blocks are enabled [On])
Select whether to reference every block
To overlay all waveforms, select
[All Blks On]
.
To overlay selected waveforms, move the flashing cursor to the num-
ber column of the reference block and select the block number.
Select
4
To display every block as its waveform is acquired
Enable tracking waveform display.
Move the flashing cursor to the
[Wave Display]
item.
Select
[On]
.
Viewing Memory Division waveforms on the Waveform screen
See:
"6.8 Seeing Block Waveforms" (p.134)
Off
Reference Blocks are not displayed (default setting)
On
Reference Blocks overlay Display blocks on the display.
All Blks Off
Set reference to all blocks to Off.
All Blks On
Set reference to all blocks to On.
Ref On-Off
Set On or Off. If
[On]
is selected, the block frame
of the selected block number is displayed as a
green square.
↑↓
Select a block.
Off
The waveform of only the last block is displayed after re-
cording up to the number of used blocks. (default setting)
On
Waveforms are displayed one block at a time as they are
acquired at each trigger event.
Display Block (Green)
Reference Block (Light Green)
Measurement data is recorded at the
colored positions.
When the Display Block is 5 and the Ref-
erence Block is 3
Reference Block No.
Enabling the Trace Waveform display
lengthens dead time.
About Dead Time:
See:
"Difference Between Dead Times
During Normal and Memory Division
Recording" (p.242)
Even if the Roll Mode is enabled (other
than Off), it is not usable when the Trace
Waveform display is disabled.
Reference Block Selection
Reference Blocks can also be selected
and deselected in the [
Ref Block]
item on
the
[List]
display.
See:
"Getting Details on Each Block:"
(p.241)
2
4
1
Trigger time
Summary of Contents for MR8740
Page 2: ......
Page 12: ...Contents x ...
Page 26: ...Operating Precautions 14 ...
Page 128: ...5 5 Miscellaneous Printing Functions 116 ...
Page 196: ...7 12 Setting Output Waveform Parameters 184 ...
Page 234: ...9 5 Numerical Calculation Type and Description 222 ...
Page 248: ...10 3 Waveform Calculation Operators and Results 236 ...
Page 302: ...12 8 FFT Analysis Modes 290 ...
Page 316: ...13 6 Editor Command Details 304 ...
Page 416: ...Appendix 4 FFT Definitions A26 ...
Page 421: ......
Page 422: ......
Page 423: ......
Page 424: ......