![Hioki MR8740 Instruction Manual Download Page 349](http://html1.mh-extra.com/html/hioki/mr8740/mr8740_instruction-manual_2137324349.webp)
16.2 External I/O (MR8741 Only)
337
13
Chapter
16 Exte
rnal
Co
ntrol (MR8741
Only)
15
16
4.
The signal for the specified state is output.
Output signal
Open drain output (with voltage output) active LOW
Output voltage
range
HIGH level: 4.0 to 5.0 V, LOW level: 0 to 0.5 V
(current value:15 mA)
Maximum input
voltage
50 VDC, 50 mA, 200 mW
HIGH
4 to 5.0 V
LOW
0 to 0.5 V
Output period
HIGH
4 to 5.0 V
LOW
0 to 0.5 V
1 ms
500
μ
s
500
μ
s
Probe Calibration Active
Probe Calibration Inactive
GND
GO/OUT1
NG/OUT2
10 k
Ω
10 k
Ω
5 V