Calculate and automatically save during data acquisition. Before measurement begins, the calcula-
tion settings need to be set.
9.4 Saving Numerical Calculation Results
When using auto save during measurement, do not remove the storage media
specified as the save destination until the measurement operation is completely
finished. Doing so may damage data on the storage media.
Procedure
To open the screen: Right-click and select
[STATUS]
→
[Num Calc]
sheet
1
Enable the saving of numerical calculation results.
Move the flashing cursor to the
[Save Calc Result]
item.
Select
[On]
. (default setting: Off)
2
Select the file creation method.
Select
Move the flashing cursor to the
[Folder to save]
item.
3
Set the save target
Move the flashing cursor to the
[Save To]
item.
Select
[Edit]
.
The Browse folders dialog box appears. (See illustration at right.)
Move the flashing cursor to the save target media.
Select
[Confirm]
to confirm the selection.
Select
To create a new folder to use as target, select
[New
Folder]
. When
[LAN]
is set as the save destination,
[New Folder]
setting is ignored and the folder named
with the current date is created.
4
Enter a save name (if you want to use a different
name).
Move the flashing cursor to the
[Save Name]
item.
Enter the save name. (default setting: MEAS)
See:
When
[LAN]
is set as the save destination,
[Save
Name]
setting is ignored and the files to be saved are
named in the previously-determined format.
See:
"Save Operations (When setting the save destination to [LAN])" (p.90)
Confirm the measurement configuration and numerical
calculation result settings, then start measurement.
New File
Creates a new file for each measure-
ment.
Existing File
Adds calculation results to one file.
USB1
Automatically save the waveform data on the USB memory stick.
LAN
Automatically save the waveform data on the PC connected via
LAN. Model 9333 LAN Communicator is required to be installed.
1
2
3
4
Save Name
• The maximum length of the Save Name string
is 123 characters. The maximum path length is
255 characters.
• A sequential number starting from 0001 is auto-
matically appended to the Save Name (when
[New File]
is selected).
Summary of Contents for MR8740
Page 2: ......
Page 12: ...Contents x ...
Page 26: ...Operating Precautions 14 ...
Page 128: ...5 5 Miscellaneous Printing Functions 116 ...
Page 196: ...7 12 Setting Output Waveform Parameters 184 ...
Page 234: ...9 5 Numerical Calculation Type and Description 222 ...
Page 248: ...10 3 Waveform Calculation Operators and Results 236 ...
Page 302: ...12 8 FFT Analysis Modes 290 ...
Page 316: ...13 6 Editor Command Details 304 ...
Page 416: ...Appendix 4 FFT Definitions A26 ...
Page 421: ......
Page 422: ......
Page 423: ......
Page 424: ......