![Hioki IM7580 Instruction Manual Download Page 285](http://html1.mh-extra.com/html/hioki/im7580/im7580_instruction-manual_2137306285.webp)
277
General Specifications
Comparator
1. Area comparator
4 parameters
Hi/IN/Lo judgment across sweep range
Judgment condition setting based on best product data available
Upper lower limit
setting range
-9.99999 G to +9.99999 G
2. Peak comparator
4 parameters
Peak range judgment (local maximum and local minimum)
Upper lower limit
setting range
-9.99999 G to +9.99999 G
Range setting
Full frequency range (for frequency sweep), full level range (for level
sweep)
Cursor function
Reading measurement values on the graph screen
A/B tracing cursors (2 numbers)
Search function
(2 types at the
same time)
Maximum value, minimum value, target (with slope specification), local maximum value and
local minimum value
Automatic search function after measurement available
Equivalent
circuit analysis
1. Circuit model
Equivalent circuit models for circuit element components
3-element models: 4 types; 4-element models: 1 type
See “4.9 Equivalent Circuit Analysis Function” (p. 124).
2. Circuit model selection method
AUTO (automatic selection), HOLD (fixed)
3. Measurement items
3-element model
L1 (inductance), C1 (capacitance), R1 (resistance), Qm (sharpness of resonance),
and sum of squares of residual error between observed values and ideal frequency
characteristics
4-element models
L1 (inductance), C1 (capacitance), R1 (resistance), C0 (parallel capacitance), Qm
(sharpness of resonance [mechanical quality factor]), K (electromechanical coupling
coefficient), and sum of squares of residual error between observed values and ideal
frequency characteristics
4. Equivalent circuit analysis execution
AUTO (executed after frequency sweep operation is completed) and MANU (executed at
user-specified timing)
5. Limitation on the sweep range used in equivalent circuit analysis
Normal sweep
Analysis is performed in the sweep range defined by the analysis
start frequency and the analysis stop frequency.
Segment sweep
Analysis is performed using the sweep range for the set segment
No.
6. Comparator
Implement comparator for analysis result
L1, C1, R1, C0, Qm: HI/IN/LO and absolute value setting
7. Resonance Frequency
The frequency (resonance frequency or antiresonance frequency) at which the
measurement value for the following measuring items is the local maximum or local
minimum can be retrieved by communication.
Z (impedance), G (conductance), B (susceptance) and Rs (equivalent series resistance)
12
Specifications
Summary of Contents for IM7580
Page 1: ......
Page 2: ......
Page 6: ...Contents iv...
Page 8: ......
Page 18: ...10 Operating Precautions...
Page 68: ...60 Judging Measurement Results...
Page 230: ...222 External Control I O Settings...
Page 234: ...226 Saving Measurement Conditions Panel Save Function Keyboard type KEY TYPE A a a...
Page 280: ...272 Editing Data Saved in USB Flash Drive...
Page 300: ...292 Measurement Time...
Page 327: ...A15 Initial Settings Table Appx 8 Initial Settings Table 10 9 8 7 6 5 4 3 2 1 Appx Ind...
Page 328: ...A16 Initial Settings Table...
Page 329: ...A17 Initial Settings Table 10 9 8 7 6 5 4 3 2 1 Appx Ind...
Page 330: ...A18 Initial Settings Table...
Page 331: ...A19 Initial Settings Table 10 9 8 7 6 5 4 3 2 1 Appx Ind...
Page 337: ...13 09...
Page 338: ......
Page 339: ......