UCM6510 IP PBX User Manual
Version 1.0.20.31
Switch Type
Select switch type.
EuroISDN:
EuroISDN (common in Europe)
NI2:
National ISDN type 2 (common in the US)
DMS100:
Nortel DMS100
4ESS:
AT&T 4ESS
5ESS:
Lucent 5ESS
NI1:
old national ISDN type 1
Q.SIG
Coding
Select "B8ZS" or "AMI".
PRI Dial Plan
This setting is used to specify the type of the callee number. The service
provider will usually verify this. The default setting is "unknown". In some
very unusual circumstances, you may need set to "Dynamic" or
"Redundant".
Note:
When one type is selected, you might not be able to dial another playlist of
numbers. For example, if "National" is configured, you will not be able to
dial local or international numbers.
PRI Local Dial Plan
This setting is used to specify the type of the caller number. The service
provider will usually verify this.
D-Chan
Indicates the D channel for control.
International Prefix
National Prefix
Local Prefix
Private Prefix
Unknown Prefix
Configure the prefix in PRI Local Dial Plan and PRI Dial Plan for each type.
PRI T310
Configure PRI T310 Timer (in seconds). The default value is 10 seconds.
PRI Indication
Select the PRI Indication.
outofband:
Use RELEASE, DISCONNECT or other messages with
CAUSE to indicate call progress (e.g., cause: unassigned number or
user busy).
inband
: use in-band tones to play busy or congestion signal to the other
side. This is the default setting.
Reset Interval
The interval that restarts idle channels.
PRI Exclusive
This setting is used to set up the ChannelID in SETUP message. If enabled,
only the specified B channel can be used. Otherwise, select one of the
channels in B channel. If you need override the existing channels selection
routine and force all PRI channels to be marked as exclusively selected,
please enable it.
Facility Enable
If selected, transmission of facility-based ISDN supplementary services
Summary of Contents for UCM6510
Page 1: ...Grandstream Networks Inc UCM6510 IP PBX User Manual ...
Page 83: ...P a g e 82 UCM6510 IP PBX User Manual Version 1 0 20 31 Figure 28 Fail2ban Settings ...
Page 273: ...P a g e 272 UCM6510 IP PBX User Manual Version 1 0 20 31 Figure 163 Black White List ...
Page 327: ...P a g e 326 UCM6510 IP PBX User Manual Version 1 0 20 31 Figure 213 Fax Sending in Web GUI ...
Page 331: ...P a g e 330 UCM6510 IP PBX User Manual Version 1 0 20 31 Figure 216 Presence Status CDR ...
Page 470: ...P a g e 469 UCM6510 IP PBX User Manual Version 1 0 20 31 Figure 334 Cleaner ...