GALaxy eHydro Elevator Controller Section 7
– Main CPU Adjustable Variables
7-55
Table 7-9: System Options
Field Variable
Min
Max
Initial
ExclusionFLT2
0
Max
Faults
0
Exclusion fault 2.
Set to fault code number. This
prevents faults from being recorded in the fault log. It
should only be set for nuisance and noncritical faults.
Controller stills goes through all the logic for each
fault code except, a call is not recorded in the fault log
ExclusionFLT3
0
Max
Faults
0
Exclusion fault 3.
Set to fault code number. This
prevents faults from being recorded in the fault log. It
should only be set for nuisance and noncritical faults.
Controller stills goes through all the logic for each
fault code except, a call is not recorded in the fault log
ExclusionFLT4
0
Max
Faults
0
Exclusion fault 4.
Set to fault code number. This
prevents faults from being recorded in the fault log. It
should only be set for nuisance and noncritical faults.
Controller stills goes through all the logic for each
fault code except, a call is not recorded in the fault log
ExclusionFLT5
0
Max
Faults
0
Exclusion fault 5.
Set to fault code number. This
prevents faults from being recorded in the fault log. It
should only be set for nuisance and noncritical faults.
Controller stills goes through all the logic for each
fault code except, a call is not recorded in the fault log
ExclusionFLT6
0
Max
Faults
0
Exclusion fault 6.
Set to fault code number. This
prevents faults from being recorded in the fault log. It
should only be set for nuisance and noncritical faults.
Controller stills goes through all the logic for each
fault code except, a call is not recorded in the fault log