GALaxy eHydro Elevator Controller Section 7
– Main CPU Adjustable Variables
7-37
Table 7-7: Group Options
Field Variable
Min
Max
Initial Units Description
HCasg SecType
0
15
0
-
Hall Call Assignment Security Type.
Use with Special
Priority Service. Determines what hall calls should be
given a special priority. Settings are
1 = Up
2 = Down
4 = Up Rear
8 = Down Rear
HCX-AssignETA
0
500
60
Sec
Hall Call Cross Assignment ETA Limit.
If ETA for hall
call assignment is greater than this ETA limit, the hall
call will be cross-assigned to the old group controller.
Invert HC Sec
0
1
0
-
Invert Hall Call Security.
1 = Hall call security inputs are secured when the
security input goes off from a normally closed switch.
Normally, the security input must be on to secure the
hall call.
IR Car
0
7
0
Car
Inconspicuous Riser Car.
This car is assigned all the IR
hall calls.
IR Control
0
7
0
Car
Inconspicuous Riser Control.
This parameter alters
how IR riser service is activated or deactivated. 0 = IR
active from ICR or RICR input.
+1 = IR activated when any IR call is activated..
+2 = Finish car calls then answer IR calls,
+4 = Finish car call before going off IR.
Nmbr Vip Cars
0
7
1
car
Number of VIP Cars.
Number of cars allow to service
VIP (priority service) calls at one time.
OTS No
HCCanc
0
1
0
-
Out of Service No Hall Call Cancelled.
Do not cancel
hall calls if cars are out of service. This is used in
accordance with cross assignment feature.