GALaxy eHydro Elevator Controller Section 6
– Main CPU Faults & Detailed Faults
6-100
SRV: SRV Service Flag
0 = Safety String
23 = Low Pressure
1 = Inspection
24 = Hot Oil
2 = Reset Mode
25 = Auto Door Off
3 = Configuration Mode
26 = Riot Control
4 = Hoistway Setup
27 = Car Sw Elevator Off
5 = Fire Fighters Stop Switch
28 = Hall Sw Elevator Off
6 = Machine Room Stop Switch
29 = Car Sw Elevator Off2
7 = Motion Stop
30 = Return to Lobby
8 = AT Floor Shutdown
31 = Independent Service
9 = Comm Fail
32 = Priority Service
10 = Door Close Fail
33 = Calibrate Load Weigher
11 = Gate and Lock
34 = Reset Jack Service
12 = Stalled
35 = Load Weigh Overload
13 = Low Oil
36 = Load Weighing Bypass
14 = Earthquake
37 = Extended Door Time
15 = Emergency Power
38 = Reset Going Up
16 = Fire Phase 2
39 = Reset Going Down
17 = Fire Phase 1 Main
40 = Security Recall
18 = Fire Phase 1 Alt
41 = TUG Service
19 = Emergency Power Recall
42 = Sabbath Service
20 = Hospital Service
43 = Attendant Service
21 = Medical Emergency Service
44 = Homing
22 = Code Blue
45 = Automatic Service
PRC: Process Flag
1 = Reset Mode
12 = Safety String Open
2 = Inspection
13 = Elevator Off Line
3 = Motion Mode: Up Fast
14 = Elevator Parked
4 = Motion Mode: Up Transition
15 = Waiting At Floor
5 = Motion Mode: Leveling Up
16 = Doors Procedure
6 = Motion Mode: Down Fast
17 = Elevator Stalled (or Low Oil)
7 = Motion Mode: Down Transition
18 = Elevator Resetting Hydro Jack
8 = Motion Mode: Leveling Down
19 = Elevator on Low Oil Pressure mode
9 = Motion Mode: Emergency Stop
20 = Elevator is in Automatic Learn Hoistway
10 = Motion Mode: Not Used
21 = Elevator is in Emergency Power
Recovery
11 = Motion Mode: Emergency Slowdown
22= Hot Oil Mode