197
Swash Detail
Swash Detail
(7) ELE PIT: elevator collective pitch mixing rate
During back and forward elevator inputs at middle collective, check if the
swash plate is raising or lowering during the input.
[Setting method]
Operate the transmitter stick in the direction you want to
set. Touch the button lit in green to enter the setting mode and adjust the
mixing rate. Do the same for the other side.
Note:
This setting can not be used when
H4-00 swash mode
is selected.
Setting ranges: 30 ~ 150% Initial value: H3-120 = 50%, except H3-120 = 100%
(8) ELE AIL: elevator aileron mixing rate
While moving the elevator back and forth at middle collective, check to
make sure the aileron axis is staying level.
[Setting method]
Operate the transmitter stick in the direction you want to
set. Touch the button lit in green to enter the setting mode and adjust the
mixing rate. Do the same for the other side.
Note:
This setting can not be used when
H4-00 swash mode
is selected.
Setting ranges: 30 ~ 150% Initial value: H3-120 = 50%, except H3-120 = 100%
(9) ELE ELE2: elevator 2nd elevator mixing rate
This parameter adjusts the elevator to 2nd elevator mixing rate. The rate
can be adjusted separately for up and down directions individually.
Note:
This setting is only available if the
H4-xx swash mode
has been
selected.
Setting ranges: 30 ~ 150% Initial value: 100%
(10) AIL High / AIL Low: Linkage compensation aileron
At HIGH pitch and LOW pitch check to make sure that the swash plate is
staying level on the elevator and collective axis when using aileron inputs.
If the swash plate is rising or falling:
[Setting method]
Operate the transmitter stick in the direction you want to
set. Touch the button lit in green to enter the setting mode and adjust the
mixing rate. Do the same for the other side.
Note
: check all four directions: high/right; high/left; low/right; low/left
Setting ranges: 0 ~ 100% Initial value: 0%
(11) AIL Dir: Compensation direction of the aileron
If the above Data (+/-) correction from 0-100 is NOT in the correct compen-
sation direction, change the value from [+] or [-].
Setting: +/- Initial setting: +
Summary of Contents for 01000141
Page 1: ...1M23Z07702 WEB FULL MANUAL ...
Page 225: ......