94
Telemetry: Receiver [Ext. battery]
Alarm set
1. Tap Alarm and choose from Buzzer, Voice,
and Inhibit.
2. Choose "Inhibit" for Vibrator if no
t
using the
vibrator alarm. If using vibrator, choose one
of the three types.
3. Tap to the Limit [4.0 V] item.
4. Adjust the rate using the "▼▼" "▼" "▲" "▲▲"
buttons.
Initial value: 4.0 V
Adjustment range: 0.0 V~100.0 V
*When the screen is tapped for one second, the rate is reset
to the initial value.
5. To terminate the input and return to the
original state, push the HOME/EXIT button.
Ext. battery
voltage
Sets the voltage on
which the alarm
operates.
↓ The "down" arrow
will indicate that an
alarm will sound when
the voltage drops to
below the setting.
Alarm is chosen from
Buzzer, Voice, and
Inhibit.
Allows Speech to be
turned ON or OFF.
● Tap the [Receiver] button in the Telemetry screen
to call the setup screen shown below.
Max. and min. values
since the power
was turned ON will
display.
Type 1
Type 2
Type 3
"Vibrator" type
If the following types are selected, the transmitter
will vibrate during the warning.
Displaying data from the EXT
battery voltage port
The EXT-VOLT screen will display the data from
the EXT-battery output from the R7108SB receiver.
In order to use this function, it is necessary to
connect external voltage connector of the R7108SB
receiver to a CA-RVIN-700 or SBS-01V to the
battery you desire to measure the voltage of the
EXT-battery
.
You will be alerted by an alarm or vibration if the
voltage set by you is exceeded.
*It cannot be used in FASST mode and S-FHSS mode.
*Only receiver voltage and EXT voltage can be used in
FASSTest12CH mode.
*The FASSTest18CH /T-FHSS mode can use all the telemetry
functions.
*CA-RVIN-700 must be installed in the aircraft.
●Return to
Linkage menu
Summary of Contents for 01000141
Page 1: ...1M23Z07702 WEB FULL MANUAL ...
Page 225: ......