Technical data
Proline Promass F 200 HART
126
Hauser
Storage temperature
–40 to +80
°
C (–40 to +176
°
F), preferably at +20
°
C (+68
°
F)
Climate class
DIN EN 60068-2-38 (test Z/AD)
Degree of protection
Transmitter
• As standard: IP66/67, type 4X enclosure
• When housing is open: IP20, type 1 enclosure
• Display module: IP22, type 1 enclosure
Sensor
IP66/67, type 4X enclosure
Shock resistance
As per IEC/EN 60068-2-31
Vibration resistance
Acceleration up to 1 g, 10 to 150 Hz, based on IEC/EN 60068-2-6
Interior cleaning
• SIP cleaning
• CIP cleaning
Electromagnetic compatibility
(EMC)
As per IEC/EN 61326 and NAMUR Recommendation 21 (NE 21)
Details are provided in the Declaration of Conformity.
17.9
Process
Medium temperature range
Sensor
• –50 to +150
°
C (–58 to +302
°
F)
• –50 to +200
°
C (–58 to +392
°
F) with extended temperature (order code for "Measuring tube
mat." option SD, SE, SF, TH)
Seals
No internal seals
Medium density
0 to 2
000 kg/m
3
(0 to 125 lb/cf)
Pressure-temperature ratings
An overview of the material load diagrams (pressure/temperature diagrams) for the process
connections is provided in the "Technical Information" document.
Secondary containment
pressure range
The sensor housing is filled with dry nitrogen and protects the electronics and mechanics inside.
DN 8 to 50 (3/8 to 2"):40 bar (580 psi)
Rupture disk
To increase the level of safety, a device version with a rupture disk with a triggering pressure of
10 to 15 bar (145 to 217.5 psi) can be used.
Flow limit
Select the nominal diameter by optimizing between the required flow range and permissible pressure
loss.
For an overview of the measuring range full scale values, see the "Measuring range" section
(