Mounting
Proline Promass F 200 HART
18
Hauser
1
2
3
4
5
A0015596
å
4
Installation in a down pipe (e.g. for batching applications)
1
Supply tank
2
Sensor
3
Orifice plate, pipe restriction
4
Valve
5
Batching tank
DN
Æ
Orifice plate, pipe restriction
[mm]
[in]
[mm]
[in]
8
3/8
6
0.24
15
½
10
0.40
25
1
14
0.55
40
1½
22
0.87
50
2
28
1.10
Orientation
The direction of the arrow on the sensor nameplate helps you to install the sensor according to the
flow direction (direction of medium flow through the piping).
Orientation
Recommendation
A
Vertical orientation
A0015591
B
Horizontal orientation, transmitter head
up
A0015589
Exception:
C
Horizontal orientation, transmitter head
down
A0015590
Exception:
D
Horizontal orientation, transmitter head
at side
A0015592
1)
Applications with high process temperatures may increase the ambient temperature. To maintain the maximum
ambient temperature for the transmitter, this orientation is recommended.