Commissioning
Proline Promass F 200 HART
80
Hauser
Assign process
variable
-
Select process
variable for totalizer.
Result
The selection
determines the
choose list of the
Unit
parameter.
• Off
• Mass flow
• Volume flow
• Corrected
volume flow
Mass flow
Unit
One of the following options is
selected in the
Assign process
variable
parameter:
• Mass flow
• Volume flow
• Corrected volume flow
Select the unit for
the process variable
of the totalizer.
Unit choose list
Country-dependent:
• kg
• lb
Totalizer operation
mode
One of the following options is
selected in the
Assign process
variable
parameter:
• Mass flow
• Volume flow
• Corrected volume flow
Select totalizer
calculation mode.
• Net flow total
• Forward flow
total
• Reverse flow total
Net flow total
Failure mode
One of the following options is
selected in the
Assign process
variable
parameter:
• Mass flow
• Volume flow
• Corrected volume flow
Define how the
totalizer behaves in
an alarm condition.
• Stop
• Actual value
• Last valid value
Stop