Proline Promass F 200 HART
Technical data
Hauser
129
Accessories
Weather protection cover
Stainless steel 1.4301
Process connections
• Flanges:
– EN 1092-1 (DIN 2501)
– Namur lengths in accordance with NE 132
– ASME B16.5
– JIS B2220
• VCO connections
• Tri-Clamp (OD tubes)
• Threaded hygienic connection:
– DIN 11851
– SMS 1145
– ISO 2853
– DIN 11864-1 Form A
• Flat flange:
DIN 11864-2 Form A
For information on the materials of the process connections (
17.11 Operability
Local operation
Display elements
• 4-line display
• In the case of order code for "Display; Operation", option
E
: white background lighting; switches
to red in event of device errors
• Format for displaying measured variables and status variables can be individually configured
• Permitted ambient temperature for the display: –20 to +60
°
C (–4 to +140
°
F)
The readability of the display may be impaired at temperatures outside the temperature range.
Operating elements
• In the case of order code "Display; Operation", Option
C
: local operation with 3 push buttons
( , ,
E
)
• In the case of order code for "Display; Operation", option
E
: external operation via touch control;
3 optical keys: , ,
E
• Operating elements also accessible in various hazardous areas
Additional functionality
• Data backup function
The device configuration can be saved in the display module.
• Data comparison function
The device configuration saved in the display module can be compared to the current device
configuration.
• Data transfer function
The transmitter configuration can be transmitted to another device using the display module.