Repair
Proline Promass F 200 HART
112
Hauser
13
Repair
13.1
General notes
Repair and conversion concept
The Hauser repair and conversion concept provides for the following:
• The measuring devices have a modular design.
• Spare parts are grouped into logical kits with the associated Installation Instructions.
• Repairs are carried out by Hauser Service or by correspondingly trained customers.
• Certified devices can be converted into other certified devices by Hauser Service or at
the factory only.
Notes for repair and conversion
For repair and modification of a measuring device, observe the following notes:
• Use only original Hauser spare parts.
• Carry out the repair according to the Installation Instructions.
• Observe the applicable standards, federal/national regulations, Ex documentation (XA) and
certificates.
• Document every repair and each conversion and enter them into the
W@M
life cycle management
database.
13.2
Spare parts
• Some interchangeable measuring device components are listed on an overview sign in the
connection compartment cover.
• This sign with an overview of the spare parts is located in the connection compartment cover of
the device and contains the following information:
– A list of the most important spare parts for the measuring device, including their ordering
information.
– The URL for the
W@M Device Viewer
):
All the spare parts for the measuring device, along with the order code, are listed here and can
be ordered. If available, users can also download the associated Installation Instructions.
Spare parts for
Spare part
Item
Part no. / structure
Sensor
1
2
3
4
5
6
7
8
9
10
Main electronic
I/O module
Cover (front)
Cover (right)
Transmitter
Display
Additionalinformation:
www
.endress
.com/dev
icev
iewer
4
7
2
6
3
5
1
1
2
A0014017
å
29
Example for "Spare part overview sign" in connection compartment cover
1
Measuring device name
2