Diagnostic
number
Short text
Remedy information
Status
signal
from the
factory
Diagnostic behavior
from the factory
Diagnostics for the electronics
242
Software incompatible
1. Check software.
2. Flash or change main electronic
module.
F
Alarm
252
Modules incompatible
1. Check electronic modules.
2. Change I/O or main electronics
module.
F
Alarm
261
Electronic modules
1. Restart device.
2. Check electronic modules.
3.Change I/O Modul or main
electronics.
F
Alarm
262
Module connection
1. Check module connections.
2. Change electronic modules.
F
Alarm
270
Main electronic failure
Change main electronic module.
F
Alarm
271
Main electronic failure
1. Restart device.
2. Change main electronic module.
F
Alarm
272
Main electronic failure
1. Restart device.
2. Contact service.
F
Alarm
273
Main electronic failure
1. Emergency operation via display.
2. Change main electronics.
F
Alarm
274
Main electronic failure
Unstable measurement!
Change main electronics.
S
Warning
*
275
I/O module failure
Change I/O module.
F
Alarm
276
I/O module failure
1. Restart device.
2. Change I/O module.
F
Alarm
282
Data storage
1. Restart device.
2. Contact service.
F
Alarm
283
Memory content
1. Transfer data or reset device.
2. Contact service.
F
Alarm
311
Electronic failure
1. Transfer data or reset device.
2. Contact service.
F
Alarm
311
Electronic failure
Maintenance required!
1. Do not perform reset.
2. Contact service.
M
Warning
*
Diagnostic behavior can be changed: "Adapting the diagnostic behavior" section (
Diagnostic
number
Short text
Remedy information
Status
signal
from the
factory
Diagnostic behavior
from the factory
Diagnostics for the configuration
410
Data transfer
1. Check connection.
2. Retry data transfer.
F
Alarm