1300 656 938
1300 301 606
Fax
Ph.
www.portableappliancetesters.com.au
QUICK REFERENCE GUIDE
SEAWARD PAC3760 PLUS
Turn appliance tester on by pressing both the ON and OFF buttons together.
CLASS I EQUIPMENT
1.
Plug appliance into the socket of the appliance tester
2.
Ensure the Earth clip is connected to an exposed metal part of appliance under test
3.
TURN APPLIANCE ON
4.
Press the Class I button
5.
If ‘LO LOAD’ appears, Leakage test may be required. Press the Class I button again to
continue
6.
Once test has complete, record test result and tag appliance
CLASS II EQUIPMENT
1.
Plug appliance into the socket of the appliance tester
2.
Ensure the Earth clip is connected to an exposed metal part of appliance OR Earth mesh
3.
TURN APPLIANCE ON
4.
Press the Class II button
5.
If ‘LO LOAD’ appears Leakage test may be required. Press the Class II button again to
continue
6.
Once test has complete, record test result and tag appliance
EXTENSION LEADS/POWERBOARDS
1.
Plug the extension lead into the front of the PAC3760 and using the extension lead adaptor
provided (RED), plug into the IEC socket
2.
PRESS the Class I button
(the PAC3760 will detect that it is an extension lead)
3.