Note
If the system contains a Rosemount 2460 System Hub it should be installed and
configured before other devices such as level gauges and temperature multiplexers.
See section
for more information on installing the
Rosemount 5900C in F
OUNDATION
Fieldbus systems.
The Rosemount 5900C supports basic configuration which is sufficient in most cases.
There are a number of advanced configuration options available as well, which may be
used for special applications when further fine-tuning is needed.
4.2.1
Basic configuration
Basic configuration includes specifying parameters for a standard configuration. This is
sufficient in most cases. A basic configuration includes the following items:
•
Measurement units
•
Tank geometry; tank height, tank type, tank bottom type, pipe diameter, hold off
distance, calibration distance, etc.
•
Process conditions; rapid level changes, turbulence, foam, solids, product dielectric
range
•
Volume; standard tank types, strapping table
•
Tank scan; analyze the Rosemount 5900C measurement signal
•
Empty tank handling; optimize measurements close to the tank bottom
4.2.2
Advanced configuration
In addition to basic configuration, the Rosemount 5900C supports advanced functions for
optimizing measurement performance in certain applications. It can be fine-tuned to
handle a wide range of product properties, various tank types, disturbing objects, and
turbulent conditions in the tank.
Examples of advanced functions supported by the Rosemount 5900C and the Rosemount
TankMaster WinSetup configuration program:
•
Surface echo tracking
•
Filter settings
for more information.
Reference Manual
Configuration
00809-0100-5901
September 2019
Rosemount 5900C Radar Level Gauge
119
Summary of Contents for Rosemount 5900C
Page 1: ...Reference Manual 00809 0100 5901 Rev DA September 2019 Rosemount 5900C Radar Level Gauge ...
Page 6: ...Contents Reference Manual September 2019 00809 0100 5901 vi Reference Manual ...
Page 12: ...Introduction Reference Manual September 2019 00809 0100 5901 12 Reference Manual ...
Page 116: ...Installation Reference Manual September 2019 00809 0100 5901 116 Reference Manual ...
Page 204: ...Configuration Reference Manual September 2019 00809 0100 5901 204 Reference Manual ...
Page 208: ...Operation Reference Manual September 2019 00809 0100 5901 208 Reference Manual ...
Page 290: ...Product Certifications Reference Manual September 2019 00809 0100 5901 290 Reference Manual ...