4.5.4
Filter setting
To open the
Filter Setting
window:
Procedure
1. In the
TankMaster WinSetup
workspace, click the right mouse button on the desired
Rosemount 5900C Radar Level Gauge icon.
2. Choose the
Properties
option from the popup menu.
3. In the
RLG Properties
window, select the
Advanced Configuration
tab.
4. Click the
Filter Setting
button:
Figure 4-10: The WinSetup Filter Setting Window
Distance Filter Factor
This parameter defines the amount of product level filtering (1 = 100%).
A low Filter Factor means that a new level value is calculated by adding a small fraction (for
instance 1%) of the level change to the last known level value. It makes the level value
steady but the device reacts slowly to level changes in the tank.
A high filter factor means that a larger fraction of the level change is added to the current
level value. This setting makes the device react quickly to level changes but the presented
level value can sometimes be somewhat jumpy.
Jump Filter
The Jump Filter is typically used for applications with turbulent surface and makes the echo
tracking work smoother as the level passes, for example, an agitator. If the surface echo is
lost and a new surface echo is found, the Jump Filter makes the level gauge wait some
Configuration
Reference Manual
September 2019
00809-0100-5901
136
Reference Manual
Summary of Contents for Rosemount 5900C
Page 1: ...Reference Manual 00809 0100 5901 Rev DA September 2019 Rosemount 5900C Radar Level Gauge ...
Page 6: ...Contents Reference Manual September 2019 00809 0100 5901 vi Reference Manual ...
Page 12: ...Introduction Reference Manual September 2019 00809 0100 5901 12 Reference Manual ...
Page 116: ...Installation Reference Manual September 2019 00809 0100 5901 116 Reference Manual ...
Page 204: ...Configuration Reference Manual September 2019 00809 0100 5901 204 Reference Manual ...
Page 208: ...Operation Reference Manual September 2019 00809 0100 5901 208 Reference Manual ...
Page 290: ...Product Certifications Reference Manual September 2019 00809 0100 5901 290 Reference Manual ...