5. Carefully fit the antenna into the still-pipe.
$
'
&
(
%
A. Closing
B. Align mark with notch on the pipe flange
C. Still-pipe flange
D. Notch that indicates direction of the Verification Pin
E. Nozzle
6. Direct the closing so that the mark aligns with the notch on the pipe flange.
7. Tighten the closing onto the still-pipe flange (customer supplied screws and nuts).
The tank is now sealed and can, as far as Rosemount Tank Gauging equipment is
concerned, be pressurized.
Note
For a safe installation on a pressurized tank it is important that the gauge is installed
in accordance with the appropriate local, national, and international standards,
codes, and practices.
8. Remove the protection cap from the waveguide.
A
A. Protection cap
Installation