Figure 3-9: Nozzle Requirements for the Rosemount 5900C with Parabolic Antenna
C
E
B
F
F
A
D
D
A. Minimum 800 mm (31 in.) for highest accuracy. Minimum 500 mm (20 in.) with
reduced accuracy.
B. Recommended height: 400 mm (16 in.). Maximum height: 600 mm (24 in.).
C. Minimum nozzle diameter: 500 mm (20 inch.)
D. Vertical plumb line
E. Ø 440 mm (17.3 in.)
F. 5° minimum
Free space requirements
The radar beam of the Rosemount 5900C with Parabolic Antenna is 10° wide. Obstacles
(construction bars, pipes larger than Ø 2", etc.) within the radar beam are generally not
accepted, as these may result in disturbing echoes. However, in most cases, a smooth tank
wall or small objects will not have any significant influence on the radar beam.
The antenna axis should be located at least 800 mm (31 in.) from the tank wall for best
performance. For evaluation contact Emerson Automation Solutions/ Rosemount Tank
Gauging.
Reference Manual
Installation
00809-0100-5901
September 2019
Rosemount 5900C Radar Level Gauge
37
Summary of Contents for Rosemount 5900C
Page 1: ...Reference Manual 00809 0100 5901 Rev DA September 2019 Rosemount 5900C Radar Level Gauge ...
Page 6: ...Contents Reference Manual September 2019 00809 0100 5901 vi Reference Manual ...
Page 12: ...Introduction Reference Manual September 2019 00809 0100 5901 12 Reference Manual ...
Page 116: ...Installation Reference Manual September 2019 00809 0100 5901 116 Reference Manual ...
Page 204: ...Configuration Reference Manual September 2019 00809 0100 5901 204 Reference Manual ...
Page 208: ...Operation Reference Manual September 2019 00809 0100 5901 208 Reference Manual ...
Page 290: ...Product Certifications Reference Manual September 2019 00809 0100 5901 290 Reference Manual ...