You can find out if such an echo exists by using the Tank Scan function when the tank is
empty. Ensure that the scan extends below the tank bottom. The tank spectrum can be
used to find suitable values for parameters such as the Extra Echo Min Distance, Extra Echo
Max Distance and Extra Echo Min Amplitude. The tank is considered empty when an echo
appears within the Min and Max Distance at an amplitude above the specified threshold.
Extra Echo Min Distance
Defines the minimum distance to the extra echo. This parameter should be greater than
the Tank Height.
Extra Echo Max Distance
Defines the maximum distance to the extra echo. This parameter should be greater than
the Extra Echo Min Distance.
Extra Echo Min Amplitude
Defines the minimum signal strength of the extra echo. If the signal strength exceeds this
value and is found in the region between Min Distance and Max Distance, the device stays
in empty tank state and presents Level=0.
Figure 4-6: Extra Echo Function
$
&
'
%
A. Amplitude
B. Distance
C. Extra Echo Max. Distance
D. Extra Echo Min. Distance
Configuration
Reference Manual
September 2019
00809-0100-5901
130
Reference Manual
Summary of Contents for Rosemount 5900C
Page 1: ...Reference Manual 00809 0100 5901 Rev DA September 2019 Rosemount 5900C Radar Level Gauge ...
Page 6: ...Contents Reference Manual September 2019 00809 0100 5901 vi Reference Manual ...
Page 12: ...Introduction Reference Manual September 2019 00809 0100 5901 12 Reference Manual ...
Page 116: ...Installation Reference Manual September 2019 00809 0100 5901 116 Reference Manual ...
Page 204: ...Configuration Reference Manual September 2019 00809 0100 5901 204 Reference Manual ...
Page 208: ...Operation Reference Manual September 2019 00809 0100 5901 208 Reference Manual ...
Page 290: ...Product Certifications Reference Manual September 2019 00809 0100 5901 290 Reference Manual ...